Rotator calibrate remotely
This revision is from 2013/12/24 01:03. You can Restore it.
Because all rotator serial ports export to TCP/IP, available communication remotely via telnet, without arduino GUI. This way available for remotely command or calibrating procedure. Rotator one export to port 91, two on 92, etc. - see section ser2net conf on status page
Example communication:
telnet 192.168.1.201 91 Trying 192.168.1.201... Connected to 192.168.1.201. Escape character is ']'. h R Rotate Azimuth Clockwise L Rotate Azimuth Counter Clockwise A Stop C Report Azimuth in Degrees M### Rotate to ### degrees MTTT XXX XXX XXX ... Timed Interval Direction Setting (TTT = Step value in seconds, XXX = Azimuth in degrees) T Start Timed Interval Tracking N Report Total Number of M Timed Interval Azimuths X1 Horizontal Rotation Low Speed X2 Horizontal Rotation Middle 1 Speed X3 Horizontal Rotation Middle 2 Speed X4 Horizontal Rotation High Speed S Stop O Offset Calibration F Full Scale Calibration c AZ=295 o Rotate to full CCW and send keystroke... Wrote to memory f Rotate to full CW and send keystroke... Wrote to memory c AZ=055