Band decoder for Arduino
This revision is from 2016/01/14 23:41. You can Restore it.
← Web page | HamShop.cz version →
The hardware
- Schematics
- PCB
Front side
- 1-14 - green LED signalized switched relay.
- 15-16 - non used outputs.
- white square - sign defines the type of equipment.
Back side
- DATA - RJ45 input data connector for Band decoder
- - TXD (UART/232 dependency internal switch).
- - GND.
- - RXD (UART/232 dependency internal switch).
- - BCD-1 input.
- - BCD-2 input.
- - +5V DC power supply.
- - BCD-3 input.
- - BCD-4 input.
- USB - +5V DC POWER supply, or upload arduino firmware.
- ETHERNET - not used.
- OUTPUTS - 14 relay outputs and GND.
How to connect Power
- plug power via usb mini cable to AC adapter, computer or usb HUB
Configure inputs
uncomment and activate only one input in source code
//=====[ Inputs ]============================================================================================= // #define INPUT_SERIAL // telnet ascii input - cvs format [band],[freq]\n (serial.h) // #define ICOM_CIV // read frequency from CIV (icom_civ.h) ** you must enabled 'CI-V transceive' in TRX settings, and disable ICOM_CIV_OUT ** // #define KENWOOD_PC // RS232 CAT (kenwood_pc.h) // #define YAESU_CAT // RS232 CAT (yaesu_cat.h) // #define YAESU_BCD // TTL BCD in A (yaesu_bcd.h) // #define ICOM_ACC // voltage 0-8V on pin4 ACC(2) connector - need calibrate in (icom_acc.h)And connect to TRX as described below
Input Serial
Activate uncomment line
#define INPUT_SERIAL
Not need any hardware settings, only send via USB to serial line ascii characters in preconfigured baudrate.
X,YYYYYYY\n
- X - band output in range 0-14, if activate BCD output range is 0-10 because 11-14 reserved for BCD. 0 (zero) = no output will be turned on.
- YYYYYYY - frequency in Hz - has no effect on the output relays, used if any CIV/CAT outputs activated.
ICOM CAT CIV
Activate uncomment line
#define ICOM_CIV
Requires baud rate and CIV addresses in setting section of source code
#define SERBAUD 9600 // [baud] Serial port in/out baudrate #define CIV_ADRESS 0x56 // HEX Icom adress (0x is prefix)
In icom_civ.h file you can set rules to select individual output relays, with a resolution of one Hz.
//=====[ Frequency (Hz) to Band rules ]====================================== // you can expand rules up to 14 Bands if (freq >= 1810000 && freq <= 2000000 ) {BAND=1;} // 160m else if (freq >= 3500000 && freq <= 3800000 ) {BAND=2;} // 80m else if (freq >= 7000000 && freq <= 7200000 ) {BAND=3;} // 40m else if (freq >= 10100000 && freq <= 10150000 ) {BAND=4;} // 30m else if (freq >= 14000000 && freq <= 14350000 ) {BAND=5;} // 20m else if (freq >= 18068000 && freq <= 18168000 ) {BAND=6;} // 17m else if (freq >= 21000000 && freq <= 21450000 ) {BAND=7;} // 15m else if (freq >= 24890000 && freq <= 24990000 ) {BAND=8;} // 12m else if (freq >= 28000000 && freq <= 29700000 ) {BAND=9;} // 10m else if (freq >= 50000000 && freq <= 52000000 ) {BAND=10;} // 6m else if (freq >= 144000000 && freq <= 146000000 ) {BAND=11;} // 2m else {BAND=0;} // out of range //===========================================================================
- short JP1 JP2
ICOM ACC(2) voltage
Hardware
- short JP3
Software
- uncommented
#define ICOM_ACC
- calibrate voltage in icom_acc.h
Yaesu BCD
Hardware
- all open
Software
- uncommented
#define YAESU_BCD
- optionaly set BCD matrix in yaesu_bcd.h
Kenwood CAT
Sniff mode
Comunicate trx only with banddecoder
Configure outputs
You can uncomment more than one output, but not all combinations are possible. See on Context table and description of parts.
//=====[ Outputs ]============================================================================================ // #define SERIAL_echo // Feedback on serial line in same baudrate, CVS format <[band],[freq]>\n // #define ICOM_CIV_OUT // send frequency to CIV ** you must set TRX CIV_ADRESS, and disable ICOM_CIV ** // #define KENWOOD_PC_OUT // send frequency to RS232 CAT ** for operation must disable KENWOOD_PC and REQUEST ** // #define YAESU_CAT_OUT // send frequency to RS232 CAT ** for operation must disable YAESU_CAT and REQUEST ** // #define BCD_OUT // output 11-14 relay used as Yaesu BCD
Firmware
Source code need configure in three steps
1. Select Inputs
- SERIAL terminal
- ICOM ACC voltage
. ICOM CI-V (optionally sniff mode)
. KENWOOD - CAT (optionally sniff mode)
- YAESU BCD
2. choose settings
3. Preset Band to output matrix
In default settings Band-1 corresponds to Relay-1, etc. You can sets any combination outputs for each band separate. With change zeros and ones in Matrix table. Band-0 reserved for out of range inputs measure.
Band 0 --> */ { 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 }, /* if inputs out of range \ Band 1 --> */ { 1, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 }, /* \ Band 2 --> */ { 0, 1, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 }, /* \ Band 3 --> */ { 0, 0, 1, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 }, /* \ Band 4 --> */ { 0, 0, 0, 1, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 }, /* \ Band 5 --> */ { 0, 0, 0, 0, 1, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 }, /* \ Band 6 --> */ { 0, 0, 0, 0, 0, 1, 0, 0, 0, 0, 0, 0, 0, 0, 0 }, /* IN ) Band 7 --> */ { 0, 0, 0, 0, 0, 0, 1, 0, 0, 0, 0, 0, 0, 0, 0 }, /* / Band 8 --> */ { 0, 0, 0, 0, 0, 0, 0, 1, 0, 0, 0, 0, 0, 0, 0 }, /* / Band 9 --> */ { 0, 0, 0, 0, 0, 0, 0, 0, 1, 0, 0, 0, 0, 0, 0 }, /* / Band 10 -> */ { 0, 0, 0, 0, 0, 0, 0, 0, 0, 1, 0, 0, 0, 0, 0 }, /* / Band 11 -> */ { 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 1, 0, 0, 0, 0 }, /* / Band 12 -> */ { 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 1, 0, 0, 0 }, /* / Band 13 -> */ { 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 1, 0, 0 }, /* Band 14 -> */ { 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 1, 0 }, /* | | | | | | | | | | | | | | V V V V V V V V V V V V V V ----------------------------------------------------------- | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 | ----------------------------------------------------------- OUTPUTS