Solutions for HAM IV rotator by DM2RM
Two wire azimuth potentiometer hardware addon from DM2RM
- R1 = your Azimuth potentiometer
- Vaz = about 3,75V (input 5V - loss on controller)
- R2 = R1/(Vaz/1,25-1)
- Accurate measurement can be achieved by reducing voltage AREF input to the maximum value of the azimuth potentiometer (Vaz).
- LM317 rezistor online calculator